Product information竊�/p>

��/span>Main technical parameter:

 

��/span> Volume (length× width ×height):

              ·370mm×340mm ×1570mm

��/span> Weight: about 90kg ���

��/span> Power supply voltage: AC220V±10% ���

                ·Frequency:50HZ ~ 60 HZ

                ·Power: 1500W

��/span> Blood pump/spare pump:

       ·Flux: 15 ~ 340ml/min (圭 6mm)

                  20 ~ 460 ml/min (圭 8mm)

��/span> Heparin pump:

       ·Flux: 0.1ml/h節�/span>10ml/h(±5%)   

       ·Precise: 0.1ml/h

       ·Injector size: 20ml/30ml/50ml

                              10ml/20ml/30ml

                              (selectable)

��/span> Arterial pressure:

    ·display scope:-300mmHg節�/span>+300mmHg

                            (±10mmHg)

��/span> Venous pressure:

    ·display scope:-50mmHg節�/span>+300mmHg

                            (±10mmHg)

��/span> Dialysate flow:

    ·300ml/min節�/span>800ml/min linearity adjustable

                          

    ·Temperature:35.0��/span>~39.0��/span>

    ·Resolving rate:0.1��/span>

    ·Conductivity:13mS/cm~15.5mS/cm

                     (±0.1 mS/cm)

 

 

 ��/span> UF flow scope: 0節�/span>1800ml/h(±30ml/h)

                          0節�/span>4000ml/h(optional)

��/span> ISO UF flow scope:0節�/span>2000ml/h(±30ml/h)

��/span> TMP:

          ·Scope:-100mmHg節�/span>+600mmHg

                      (±20mmHg)

��/span> Blood leakage monitor:

          ·over 1ml blood per liter dialysate

            (flow:500ml/min)

��/span> Blood level monitor: ultrasonic sensor

��/span> Air bubble monitor:

         ·Infrared and response threshold value:

          Single air bubble of 200 龜 I exists when

          Blood flux is 200ml/min

��/span> Inflow pressure: 0MPa節�/span>0.6MPa

��/span> Inflow temperature: 5���30��/span>

��/span> Environment temperature: 10���30��/span>,

         ·Relative humidity70%

��/span> Rinse/disinfection: chemical disinfection

    (citric acid,peracetic acid and oxalic acid)

��/span> Hot rinse: 80��/span>

��/span> Back-up power supply: last for 15-30min

    after electric-cut.(optional)

 

 

��/span>JH-2000 function

 

    Be capable to do hemodialysis,hemoperfusion,plasma exchange and pure UF treatment.If use 120L RO water in one container,hemodialysis treatment can be done for 4 hours and hemofiltration CRRT treatment can be done if the machine work with JHBP-2000B blood pump and electric balance.

 

��/span>Clinical application

 

· Hemodialysis therapy:

    Mainly suitable for all kinds of acute and chronic kidney failure patient.

· Pure ultrafiltration therapy:

    Mainly suitable for patients with excessive water stored in the body due to acute,chronic kidney failure or incomplete heart function.

· Hemoperfusion therapy:

    Mainly applies in the acute drug poisoning.Patients whose condition still continue worsening after some rescue measures such as gastric lavage,catharsis,infusion and forced diuresis should consider this therapy, especially those accompanied by the brain function barrier or stuper,liver and kidney function barrier,old patients whose tissue protein is highly combined with medicine and metabolite(such as organic phosphorus agricultural chemicals),and who takes medicine oversized which had achieved the toxicant lethal dose density or exceed 30% of their own elimination ability are also suitable for hemoperfusion therapy.

· Plasma exchange therapy:

 

Mainly suitable for the immunity diseases;acute nephritis,lupous nephritis,frequent myeloma nephrosis, serious myasthenia,acute liver function failure,thyroid gland crisis,ethnic hypercholesterolemia, HVS, acute-chronic rejection prior to/after kidney transplant,transplant recurs nephritis,acute demyelination multimental illness(Grimm Bari syndrome),selfimmunity hemolytic anemia,selfimmunity blood platelet reduced purpura, hemolytic uremia syndrome,the cold globin proteinemia, yellow hepatatrophia. 




Inquire now